SAI533-H63
Yokogawa
T/T
1 year
Availability: | |
---|---|
Quantity: | |
Yokogawa Main Products
AAT145-S00 | VI701 | ST2*D |
ADV151-P03 | VI702 | VM1*D |
ADV151-P00 | PW302 | ST3*A |
AAI143-S00 | CP345 | PAC*A |
AAR181-S00 | AIP532 | NM29*A |
AAP135-S00 | AIP502 | ALU4*D |
ADV551-P00 | AIP601 | CTL4*B |
Description
Input elements 1 through 3 consist of a voltage input circuit and a current input circuit. The input circuits are mutually isolated. They are also isolated from the case. The voltage signal that is applied to the voltage input terminal (U, ±) is normalized using the voltage divider and the operational amplifier (op-amp) of the voltage input circuit . It is then sent to a voltage A/D converter. The current input circuit is equipped with two types of input terminals, a current input terminal (I, ±) and an optional current sensor input connector (EXT). Only one can be used at any given time. The voltage signal from the current sensor that is received at the current sensor input connector is normalized using the voltage divider and the operational amplifier (op-amp). It is then sent to a current A/D converter. The current signal that is applied to the current input terminal is converted to a voltage signal by a shunt. Then, it is sent to the current A/D converter in the same fashion as the voltage signal from the current sensor. The voltage signal that is applied to the voltage A/D converter and current A/D converter is converted to digital values at an interval of approximately 10 µs. These digital values are isolated by the isolator and passed to the DSP. In the DSP, the measured values are derived based on the digital values. The measured values are then transmitted to the CPU. The measured values and computed values are displayed and transmitted as measurement functions of normal measurement.
Strong PLC Parts Series:
ABB PLC
DCS 800xA System/S800 I/O System, ADCS 800xA System/S900 I/O Series, Advant OCS/800XA , H&B Freelance 2000 , BAILEY-INFI90/Bailey Net 90, DSQC Robot Parts, PLC cards and boards
Honeywell DCS
Experion PKS ( C200 , C300 ), FSC
Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
Fanuc PLC
IC695, IC698, IC694, IC697, IC754, IC752 QuickPanel, IC660, IC600 Seriex Six, IC610, IC620 Series One, IC692 Series 90-20, IS200, IS215, DS200, DS3000/3800
Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
More Products
AAI143-H00 S1 | NP1PU-048E | 140NOE77110 | 5X00419G02 |
AAI143-H00/K4A00 | NP1X1606-W | 140CPS22400 | 405A675G33 |
AAI143-H03 | NP1L-RD1 | 140DRC83000 | 5A22404G01 |
AAI143-S00 | CTHMIMOD-00 | ATV61HD37N4 | 5X00109G02 |
AAI143-S00/A4S00 | NB2W56R | 140CPS21400 | 5A23292G09 |
AAI143-S00/k4a00 | NP1AXH8V-MR | 140CRA93200 | 9942A34G17 |
AAI143-S03/A4S00 | NP1W1606T | 490NRP25300 | 5A26479G07 |
AAI543 | NP1F-MM1 | 140AII33010 | 3A99795H04 |
AAI543-H00 | FTU612A | 140XTS00200 | 4D33857G01 |
AAI543-H00 S1 | FGU130B | 140CRP81100 | 2840A21G01 |
AAI543-H00/K4A00 | FNC160A-C20 | AS-B805-016 | 5X00444G02 |
Our services
We double check and test the goods before shipping, we have experienced and dedicated technical staff for inspecting every module and card as to ensure the end user use them perfectly without any probelm and added trouble.
We help customer save cost with high quality and comparative price. We care about what customer care, and see the end user's benefits as important, we would like to build long-term business relationship with customers.
Yokogawa Main Products
AAT145-S00 | VI701 | ST2*D |
ADV151-P03 | VI702 | VM1*D |
ADV151-P00 | PW302 | ST3*A |
AAI143-S00 | CP345 | PAC*A |
AAR181-S00 | AIP532 | NM29*A |
AAP135-S00 | AIP502 | ALU4*D |
ADV551-P00 | AIP601 | CTL4*B |
Description
Input elements 1 through 3 consist of a voltage input circuit and a current input circuit. The input circuits are mutually isolated. They are also isolated from the case. The voltage signal that is applied to the voltage input terminal (U, ±) is normalized using the voltage divider and the operational amplifier (op-amp) of the voltage input circuit . It is then sent to a voltage A/D converter. The current input circuit is equipped with two types of input terminals, a current input terminal (I, ±) and an optional current sensor input connector (EXT). Only one can be used at any given time. The voltage signal from the current sensor that is received at the current sensor input connector is normalized using the voltage divider and the operational amplifier (op-amp). It is then sent to a current A/D converter. The current signal that is applied to the current input terminal is converted to a voltage signal by a shunt. Then, it is sent to the current A/D converter in the same fashion as the voltage signal from the current sensor. The voltage signal that is applied to the voltage A/D converter and current A/D converter is converted to digital values at an interval of approximately 10 µs. These digital values are isolated by the isolator and passed to the DSP. In the DSP, the measured values are derived based on the digital values. The measured values are then transmitted to the CPU. The measured values and computed values are displayed and transmitted as measurement functions of normal measurement.
Strong PLC Parts Series:
ABB PLC
DCS 800xA System/S800 I/O System, ADCS 800xA System/S900 I/O Series, Advant OCS/800XA , H&B Freelance 2000 , BAILEY-INFI90/Bailey Net 90, DSQC Robot Parts, PLC cards and boards
Honeywell DCS
Experion PKS ( C200 , C300 ), FSC
Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
Fanuc PLC
IC695, IC698, IC694, IC697, IC754, IC752 QuickPanel, IC660, IC600 Seriex Six, IC610, IC620 Series One, IC692 Series 90-20, IS200, IS215, DS200, DS3000/3800
Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
More Products
AAI143-H00 S1 | NP1PU-048E | 140NOE77110 | 5X00419G02 |
AAI143-H00/K4A00 | NP1X1606-W | 140CPS22400 | 405A675G33 |
AAI143-H03 | NP1L-RD1 | 140DRC83000 | 5A22404G01 |
AAI143-S00 | CTHMIMOD-00 | ATV61HD37N4 | 5X00109G02 |
AAI143-S00/A4S00 | NB2W56R | 140CPS21400 | 5A23292G09 |
AAI143-S00/k4a00 | NP1AXH8V-MR | 140CRA93200 | 9942A34G17 |
AAI143-S03/A4S00 | NP1W1606T | 490NRP25300 | 5A26479G07 |
AAI543 | NP1F-MM1 | 140AII33010 | 3A99795H04 |
AAI543-H00 | FTU612A | 140XTS00200 | 4D33857G01 |
AAI543-H00 S1 | FGU130B | 140CRP81100 | 2840A21G01 |
AAI543-H00/K4A00 | FNC160A-C20 | AS-B805-016 | 5X00444G02 |
Our services
We double check and test the goods before shipping, we have experienced and dedicated technical staff for inspecting every module and card as to ensure the end user use them perfectly without any probelm and added trouble.
We help customer save cost with high quality and comparative price. We care about what customer care, and see the end user's benefits as important, we would like to build long-term business relationship with customers.