Hima F4204 Module
Home » Products » HIMA » Hima F4204 Module

Product Category

Contact Us

Email:sales3@5gplc.com

Address:No.601, Hongwen Liuli, Siming District, Xiamen, China

Hima F4204 Module Hima F4204 Module
Hima F4204 Module Hima F4204 Module
Hima F4204 Module Hima F4204 Module

loading

Hima F4204 Module

HIMA F4204 Module
  • F4204

  • HIMA

  • T/T

  • 1 year

Availability:
Quantity:

Hima Main Serise:

1. CPU: F8650X, F8650E, F8641
2. Power Distribution Module: F7130A, F7130, F7131, F7133
3. Communication MODULE Coprocessor MODULE; F8621A, F8627X, F8628, F8628X

4. Input Module: F3221, F3222, F3223, F3224, F3236, F3237, F6208, F6214, F6215, F6216, F6216A, F6217, F6220, F6221
5. OUTPUT MODULE: F3330, F3331, F3332, F3333, F3334, F3322, F7126, F6705, F1DI1601, F3DIO8/801, F2DO1602, F3DIO20/802, F3AIO8/401, F60GEH01, F60PS01, F60DIO24/1601, F60DI3201, Z7116, Z7126, Z7127, Z7138, Z7128
6. I/O bus link module block: F7553


Hima Main Products

F1101F3423F6705
F2201F4111AF7105A
F3113AF4204F7126
F3221F6214F7130
F3236F6217F7130A
F3237F6705F7131
F3322F7105AF7133
F3330F7126F7553


Description

Line control is used to detect short-circuits or open-circuits and can be configured for the remote I/O, e.g., on EMERGENCY STOP inputs complying with Cat. 4 in accordance with EN 954-1. The remote I/O pulses the pulsed outputs to detect short-circuits and open-circuits on the digital inputs (DI). To do so, configure the Value.[BOOL] -> system variable in SILworX and the DO[0x].Value system signal in ELOP II Factory. The variables for the pulsed outputs must begin with channel 1 and reside in direct sequence, one after the other. If the following faults occur, the FAULT LED located on the front plate of the controller blinks, the inputs are set to low level and an (evaluable) error code is created: ƒ Cross-circuit between two parallel lines, ƒ Improper connections of two lines (e.g., TO 2 to DI 3), ƒ Earth fault of a line (with earthed ground only), ƒ Open-circuit or open contacts, i.e., including when one of the two EMERGENCY STOP switches mentioned above has been engaged, the FAULT LED blinks and the error code is created. For more information on how to configure line control in the user program, refer to the HIMatrix Engineering Manual HI 800 101 E.


More Products

IC200PNS002FBM202 P0914ST345107EA90-S GJR5251200R0101
IC695PSA140FBM2313501E07EB62R1
DS3800NMEC1K1KFBM241c P0914WM348107KP60R101
DS200PCCAG10ACBFBM214320107KP64 GJR5240600R0101
IC698CPE010FBM206 P0916CQ4352B07KP90
IC697CPM925FBM217238107KR264
IC695RMX128FCM10E3603B07KR51
DS200PCCAG5ACBP0972VA ATS3708E07KR91 GJR5250000R0101
DS200LDCCH1 DS200LDCCH1ALAP0903CW411807KT92
IC693BEM340FBM215432907KT92 GJR5250500R0262
IS200TRLYH1BED FBM201 P0914SQ310107KT92 GJR5250500R0902


Delivery Time

We accept Westem Union,T/T.

We cooperate with T/T, Western Union. You can receive the goods within 3 to 5 days.


About us

Our company is a professional engaged in the large-scale system (distributed control system, programmable controller, redundant fault-tolerant control systems, robot control system, large servo control system is the central feeding system plastic molding auxiliary equipment and automation of whole plant planning) imported automation system such as spare parts, modules, sales and system integration of high-tech enterprises. The company is equipped with professional technicians to provide customers with better service.


Previous: 
Next: