1756-EN2F
Allen Bradley
T/T
12 Months
Availability: | |
---|---|
Quantity: | |
Allen Bradley 1756-EN2F Communication Module
1756-EN2F:
EtherNet/IP communication rate: 100 Mbps
Current draw @ 5.1V DC: 1.2 A
Current draw @ 24V DC: 3 mA
Power dissipation: 6.2 W
Thermal dissipation: 21.28 BTU/hr
Isolation voltage: 30V (continuous), basic insulation type
Ethernet port: 1 Ethernet fiber
Ethernet cable: Multimode fiber, LC connector
USB port: 3 - on USB ports
North American temp code: T4A
Enclosure type rating: None (open-style)
Temperature, operating:
Series C Chassis: 0 to +60 °C (+32 to +140 °F)
Series B Chassis: 0 to +50 °C (+32 to +122 °F)
Temperature, storage: -40 to +85 °C (-40 to +185 °F)
Relative humidity: 5% to 95% non-condensing
Vibration: 2 g @ 10 to 500 Hz
Shock, operating and nonoperating: 30 g
Emission: CISPR 11 (IEC 61000-6-4) Class A
ESD immunity: 6 kV contact discharges, 8 kV air discharges
Radiated RF immunity:
10V/m with 1 kHz sine wave 80% AM from 80 to 2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
3V/m with 1 kHz sine wave 80% AM from 2000 to 6000 MHz
EFT/B immunity: ±3 kV at 5 kHz on Ethernet ports
Surge transient immunity: ±2 kV line-earth (CM) on Ethernet ports
Conducted RF immunity: 10V rms with 1 kHz sine wave 80% AM from 150 kHz to 80 MHz
2711-T10C15 | 1756-OW16I | 1756-IB16 |
2711-T10C20 | 1756-IB32 | 2711P-RN6 |
1756-CNBR | 1756-PA75 | 2711P-RP1 |
1747-L541 | 1747-L541 | 2711P-RP2A |
1757-SRM | 1756-OBI6E | 1771-A1B |
2711-NC13 | 1756-OB16I | 1756-DHRIO |
1756-EN2T | 1756-IB16I | 1756-OF8H |
1746-NI4 | 1746-OW8/A | 1756-TBCH |
1756-BA2 | 1746-OB16/D | 1747-SN/B |
1771-IMD/B | 1756-OF4/A | 1746-NI4/A |
1771-OBD/C | 1756-IF16 | 1747-BA |
1771-P6R C | 1746-A7/B | 1794-OB16 |
1771-P6S B | 1756-EN2T | 1794-IB16 |
1785-BCM/C | 1746-A13 | 1756-OB16E |
Allen Bradley 1756-EN2F Communication Module
1756-EN2F:
EtherNet/IP communication rate: 100 Mbps
Current draw @ 5.1V DC: 1.2 A
Current draw @ 24V DC: 3 mA
Power dissipation: 6.2 W
Thermal dissipation: 21.28 BTU/hr
Isolation voltage: 30V (continuous), basic insulation type
Ethernet port: 1 Ethernet fiber
Ethernet cable: Multimode fiber, LC connector
USB port: 3 - on USB ports
North American temp code: T4A
Enclosure type rating: None (open-style)
Temperature, operating:
Series C Chassis: 0 to +60 °C (+32 to +140 °F)
Series B Chassis: 0 to +50 °C (+32 to +122 °F)
Temperature, storage: -40 to +85 °C (-40 to +185 °F)
Relative humidity: 5% to 95% non-condensing
Vibration: 2 g @ 10 to 500 Hz
Shock, operating and nonoperating: 30 g
Emission: CISPR 11 (IEC 61000-6-4) Class A
ESD immunity: 6 kV contact discharges, 8 kV air discharges
Radiated RF immunity:
10V/m with 1 kHz sine wave 80% AM from 80 to 2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
3V/m with 1 kHz sine wave 80% AM from 2000 to 6000 MHz
EFT/B immunity: ±3 kV at 5 kHz on Ethernet ports
Surge transient immunity: ±2 kV line-earth (CM) on Ethernet ports
Conducted RF immunity: 10V rms with 1 kHz sine wave 80% AM from 150 kHz to 80 MHz
2711-T10C15 | 1756-OW16I | 1756-IB16 |
2711-T10C20 | 1756-IB32 | 2711P-RN6 |
1756-CNBR | 1756-PA75 | 2711P-RP1 |
1747-L541 | 1747-L541 | 2711P-RP2A |
1757-SRM | 1756-OBI6E | 1771-A1B |
2711-NC13 | 1756-OB16I | 1756-DHRIO |
1756-EN2T | 1756-IB16I | 1756-OF8H |
1746-NI4 | 1746-OW8/A | 1756-TBCH |
1756-BA2 | 1746-OB16/D | 1747-SN/B |
1771-IMD/B | 1756-OF4/A | 1746-NI4/A |
1771-OBD/C | 1756-IF16 | 1747-BA |
1771-P6R C | 1746-A7/B | 1794-OB16 |
1771-P6S B | 1756-EN2T | 1794-IB16 |
1785-BCM/C | 1746-A13 | 1756-OB16E |