  • 1606-XLS240-UPS

  • Allen Bradley

  • T/T

  • 12 Months

Availability:
Quantity:


Technical Specifications for Rockwell Automation 1606-XLS240-UPS:

Input:

  • Nominal Voltage: 24V DC

  • Voltage Ranges:

    • Continuous Operation: 22.5 to 30V DC (see Fig. 5-1)

    • Temporarily Allowed: 30 to 35V DC (no damage to the DC-UPS)

    • Absolute Maximum: 35V DC (no damage to the DC-UPS)

    • Buffer Mode Activation: 0 to 22.5V DC (if the input was above the turn-on level and all buffer conditions are fulfilled)

  • Allowed Input Voltage Ripple:

    • <400Hz Bandwidth: Max. 1.5Vpp

    • 400Hz to 1kHz Bandwidth: Max. 1Vpp

  • Allowed Voltage Between Input and Earth (Ground): Max. 60V DC or 42.4V AC

  • Turn-on Voltage:

    • Typical: 22.8V DC (the output does not switch on if the input voltage does not exceed this level)

    • Maximum: 23V DC

  • Input Current:

    • Internal Current Consumption (Typical): 120mA

    • Battery Charging (Typical): 1.1A (constant current mode at 24V input, see Fig. 8-2)

Output in Normal Mode:

  • Nominal Voltage: 24V DC (follows the input voltage reduced by the input to output voltage drop)

  • Voltage Drop Between Input and Output:

    • Maximum: 0.3V at 10A output current (see Fig. 6-1 for typical values)

    • Maximum: 0.45V at 15A output current (see Fig. 6-1 for typical values)

  • Ripple and Noise Voltage: Max. 20mVpp (20Hz to 20MHz, 50 Ohm)

  • Nominal Current: 15A (continuously allowed)

  • Nominal Power: 360W (continuously allowed)

  • Short-Circuit Current:

    • Minimum: 17.9A (load impedance 100mOhm, see Fig. 6-2 for typical values)

    • Maximum: 21A (load impedance 100mOhm, see Fig. 6-2 for typical values)

Environmental:

  • Operating Temperature Range: -25°C to +70°C

  • Derating: 0.43A/°C from +60°C to +70°C (normal mode)

  • Dimensions: 49mm (W) x 124mm (H) x 117mm (D)

  • Buffer Time (at 10A):

    • Typical: 6 minutes 45 seconds with a 7Ah battery module

    • Typical: 55 minutes with a 26Ah battery module



2711-T10C151756-OW16I1756-IB16
2711-T10C201756-IB322711P-RN6
1756-CNBR1756-PA752711P-RP1
1747-L5411747-L5412711P-RP2A
1757-SRM1756-OBI6E1771-A1B
2711-NC131756-OB16I1756-DHRIO
1756-EN2T1756-IB16I1756-OF8H
1746-NI41746-OW8/A1756-TBCH
1756-BA21746-OB16/D1747-SN/B
1771-IMD/B1756-OF4/A1746-NI4/A
1771-OBD/C1756-IF161747-BA
1771-P6R C1746-A7/B1794-OB16
1771-P6S B1756-EN2T1794-IB16