Manufacturer: Honeywell
Product No.: LG1093AC05
Product Type: LG Flame Detector
The Honeywell LG/EG flame monitoring system detects UV radiation from hydrocarbon flames and provides an output signal to indicate flame presence or absence. It has been successfully used on General Electric (GE) and GE licensee gas turbines for over 35 years.
Sensor Type: Geiger Mueller-type sensor phototube
Detection Range: UV radiation in the 180–260 nm spectrum
Sensitivity: High sensitivity with a fast Flame Present Response Time (0.1 sec typical)
Flame Loss Response Time: 0.2 sec max
Operating Distance: Up to 330 m (1000 ft) sensor to amplifier
Temperature Range: -40°C to 176°C
Shelf Life: Two years
MTBF: 10,000 hours, with over one billion operating hours
Flame Sensor Dimensions: 1.73" O.D. by 0.14" wide flange
Cable: 2-conductor armored cable, 24 ft (7.3 m) length
Viewing Window Rating: 428 mbar (6.3 psi)
EG1033AA: Transistor open collector
EG1033AB and EG1033AC: Relay contacts (SPDT)
Voltage Requirements:
28 VDC
20-35 VDC
115 VAC
European Directive CE Mark:
EMC 89/336/EEC
LVD 73/23/EEC
ATEX Explosive Atmosphere 94/9/EC (EEx d IIA T3 or EEX d IIC T3, Zone 1 and 2)
Factory Mutual Approval:
Class I, Div 1 and 2, Groups B, C, and D
The LG1093 series may not function as expected on GE/NP DLE gas turbines (Low-NOx). Pre-selected LG1093's are needed for these applications and are not available through Honeywell.
Weight: 0.91 kg
Shipping Weight: 3 kg
INST Automation PLC Limited
Vicky Chi
sales3@5gplc.com
+86 18144155716 (Whats-app, Skype, Wechat)
Recommend modules:
Manufacturer: Honeywell
Product No.: LG1093AC05
Product Type: LG Flame Detector
The Honeywell LG/EG flame monitoring system detects UV radiation from hydrocarbon flames and provides an output signal to indicate flame presence or absence. It has been successfully used on General Electric (GE) and GE licensee gas turbines for over 35 years.
Sensor Type: Geiger Mueller-type sensor phototube
Detection Range: UV radiation in the 180–260 nm spectrum
Sensitivity: High sensitivity with a fast Flame Present Response Time (0.1 sec typical)
Flame Loss Response Time: 0.2 sec max
Operating Distance: Up to 330 m (1000 ft) sensor to amplifier
Temperature Range: -40°C to 176°C
Shelf Life: Two years
MTBF: 10,000 hours, with over one billion operating hours
Flame Sensor Dimensions: 1.73" O.D. by 0.14" wide flange
Cable: 2-conductor armored cable, 24 ft (7.3 m) length
Viewing Window Rating: 428 mbar (6.3 psi)
EG1033AA: Transistor open collector
EG1033AB and EG1033AC: Relay contacts (SPDT)
Voltage Requirements:
28 VDC
20-35 VDC
115 VAC
European Directive CE Mark:
EMC 89/336/EEC
LVD 73/23/EEC
ATEX Explosive Atmosphere 94/9/EC (EEx d IIA T3 or EEX d IIC T3, Zone 1 and 2)
Factory Mutual Approval:
Class I, Div 1 and 2, Groups B, C, and D
The LG1093 series may not function as expected on GE/NP DLE gas turbines (Low-NOx). Pre-selected LG1093's are needed for these applications and are not available through Honeywell.
Weight: 0.91 kg
Shipping Weight: 3 kg