Product Type: LG Flame Detector
The Honeywell LG/EG flame monitoring system detects UV radiation emitted by a hydrocarbon flame and provides an output signal indicating flame or no-flame conditions. It has been used successfully for over 35 years in General Electric (GE) and GE licensee gas turbines.
Sensor Type: Geiger Mueller-type sensor phototube
Detection Range: UV radiation in the 180–260 nm spectrum
Sensitivity: High sensitivity with a fast Flame Present Response Time (0.1 sec typical)
Flame Loss Response Time: 0.2 sec max
Operating Distance: Up to 330 m (1000 ft) sensor to amplifier
Temperature Range: -40°C to 176°C
Shelf Life: Two years
MTBF: 10,000 hours, with over one billion operating hours
Flame Sensor Dimensions: 1.73" O.D. by 0.14" wide flange
Cable: 2-conductor armored cable, 9 ft (2.7 m) length
Viewing Window Rating: 428 mbar (6.3 psi)
EG1033AA: Transistor open collector
EG1033AB and EG1033AC: Relay contacts (SPDT)
Voltage Requirements:
28 VDC
20-35 VDC
115 VAC
European Directive CE Mark:
EMC 89/336/EEC
LVD 73/23/EEC
ATEX Explosive Atmosphere 94/9/EC (EEx d IIA T3 or EEX d IIC T3, Zone 1 and 2)
Factory Mutual Approval:
Class I, Div 1 and 2, Groups B, C, and D
The LG1093 series may not work as expected on GE/NP DLE gas turbines (Low-NOx). Special pre-selected LG1093's are needed for these applications and are not available via Honeywell.
Weight: 0.91 kg
Shipping Weight: 3 kg
INST Automation PLC Limited
Vicky Chi
sales3@5gplc.com
+86 18144155716 (Whats-app, Skype, Wechat)
Recommend modules:
Manufacturer: Honeywell
Product No.: LG1093AC01
Product Type: LG Flame Detector
The Honeywell LG/EG flame monitoring system detects UV radiation emitted by a hydrocarbon flame and provides an output signal indicating flame or no-flame conditions. It has been used successfully for over 35 years in General Electric (GE) and GE licensee gas turbines.
Sensor Type: Geiger Mueller-type sensor phototube
Detection Range: UV radiation in the 180–260 nm spectrum
Sensitivity: High sensitivity with a fast Flame Present Response Time (0.1 sec typical)
Flame Loss Response Time: 0.2 sec max
Operating Distance: Up to 330 m (1000 ft) sensor to amplifier
Temperature Range: -40°C to 176°C
Shelf Life: Two years
MTBF: 10,000 hours, with over one billion operating hours
Flame Sensor Dimensions: 1.73" O.D. by 0.14" wide flange
Cable: 2-conductor armored cable, 9 ft (2.7 m) length
Viewing Window Rating: 428 mbar (6.3 psi)
EG1033AA: Transistor open collector
EG1033AB and EG1033AC: Relay contacts (SPDT)
Voltage Requirements:
28 VDC
20-35 VDC
115 VAC
European Directive CE Mark:
EMC 89/336/EEC
LVD 73/23/EEC
ATEX Explosive Atmosphere 94/9/EC (EEx d IIA T3 or EEX d IIC T3, Zone 1 and 2)
Factory Mutual Approval:
Class I, Div 1 and 2, Groups B, C, and D
The LG1093 series may not work as expected on GE/NP DLE gas turbines (Low-NOx). Special pre-selected LG1093's are needed for these applications and are not available via Honeywell.
Weight: 0.91 kg
Shipping Weight: 3 kg